KEMPEROL 2K PUR PDF

KEMPEROL 2K-PUR is a two-component, UV-stable high performance seamless and self-terminating cold fluid-applied polyester reinforced solvent-free. KEMPEROL 2K-PUR Speedshot combined with KEMPEROL 2K-PUR is the ideal solution for all applications where speed is essential. These include balconies. KEMPEROL® 2K-PUR is a solvent-free and odourless, fully reinforced, polyurethane resin-based liquid waterproofing system. It is ideal for use on sustainablility.

Author: Yozuru Jugami
Country: Ukraine
Language: English (Spanish)
Genre: Literature
Published (Last): 28 August 2016
Pages: 443
PDF File Size: 11.62 Mb
ePub File Size: 2.59 Mb
ISBN: 173-9-82894-158-9
Downloads: 94720
Price: Free* [*Free Regsitration Required]
Uploader: Dukree

Kemperol 2K-PUR highly permeable roofing membrane

After completion of mineral aggregate surfacing, avoid any traffic for a minimum of 3 days. For each product specified, two samples, minimum size 6 inches mm square, representing actual product, thickness, color, texture and surfacing. Application of waterproofing membrane may proceed while air temperature is between 40 degrees F 5 degrees C and 90 degrees F 30 degrees C providing the substrate is a minimum of 5 degrees F above the dew point. Concrete and Masonry Substrate Leveling and Patching: Perform leveling and patching operations as follows:.

Kemperol 2K-PUR – Kemper System Ltd

It is ideal for use on kempedol based projects or on sensitive occupied buildings where the strong odours and fumes from solvent-based products could be disruptive.

Appearance of the saturated fleece should be light opaque amber with no white spots. All temporary closures shall be made as recommended or required by the membrane manufacturer. Temporary flashings are not allowed without prior written approval from the Membrane manufacturer. Mix accelerator with the spiral agitator for 2 minutes or until both liquids are thoroughly blended.

  DISGO NET BROWSER 3000 MANUAL PDF

Allow the surfacing mix to self-level and reach an initial set for minutes until material will retain a peak after being touched by a finger.

Aggregate shall be applied to excess to obtain uniform and full coverage. Following full curing of primer, apply waterproofing resin and a 4 inch 10 cm wide strip of membrane resin and fleece in strict accordance with Membrane manufacturer’s written instructions.

Supports for electrical conduit and gas lines greater than 1 inch in diameter require the use of a separate engineered support system.

Kemperol 2K-PUR

Additional adhesive is required in the corner and perimeter regions of the roof. Various Kemper warranties are available. Extend preparation a minimum of 1 inch beyond the termination of the membrane flashing materials. Completion of flashings, terminations, and temporary closures shall be completed as required pkr provide a watertight condition.

Ejot Srbija -specijalista u tehnologiji povezivanja. KEMPEROL 2K PUR

Concrete shall be abrasively cleaned in accordance with ASTM D to provide a sound substrate free from laitance. Pour entire resin Component B into entire resin Component A and thoroughly mix components with a clean spiral agitator. Embed Get technical help. Strip all plywood joints with fleece reinforcement imbedded into the wet primer or resin.

Aggregate Finish Bonding Resin: Tile adhesive shall meet and exceed ANSI requirements for pr shear strength.

  2WIRE 3801 PDF

Pre-mix single-component and two-component coatings prior to application to achieve an even consistency. There must be a minimum of a 2 inch 5 cm overlap between vertical and horizontal flashing components.

Hanover Architectural Products, freeze-thaw resistant precast concrete pavers, minimum 2 inch thickness, with the following characteristics:.

Membrane manufacturer shall provide the services of a competent field representative on-site to provide the following inspections:. Fleece will begin to rapidly saturate with the liquid resin mix.

Note that all insulation requires cover board. Do not apply Kemperol membrane to tacky or wet primer Membrane must be applied to primer only when completely dry and without tack.

R-5 per inch RSI 0. Solid to walk on: Non-Moving Cracks, Joints, and Voids: Upon request of the Architect or Owner, submit Manufacturer’s written approval of secondary components in list form, signed by an authorized agent of the manufacturer. The fleece can only hold so much resin and all excess should be rolled forward to the unsaturated fleece, eliminating ponding or excessive build-up of the resin. Channel water retention mat into an internal drain or perimeter drain system.